Reliable Corrosive Gas Testing for IEC 60068-2-42 & IEC 60068-2-60 Compliance
LIB industry noxious gas test chamber enables manufacturers to identify corrosion risks early by accurately simulating real-world exposure to temperature, humidity and trace corrosive gases.
Low-level gases such as SO₂, H₂S and NO₂ can cause long-term damage to metals, coatings and electronic components, often leading to unexpected failures in service.
By providing precise control of gas concentration, temperature and humidity, the system supports IEC 60068-2-42 and IEC 60068-2-60 compliant single and mixed gas testing, delivering repeatable and trustworthy corrosion evaluation results.
Flexible reach-in, walk-in and customized configurations ensure the solution adapts to your specific testing requirements.
Model: GCM-100, GCM-225, GCM-500, GCM-800, GCM-1000
Standard: ISO 6988, ISO 3231, DIN 50018, ASTM G87-02, IEC 60950:22, IEC 60068-2-42, IEC60068-2-60,EIA-364-65
You may also be interested in: Ozone Test Chamber | SO2 Corrosion Chamber
Watch Noxious gas test chamber In Action
Features and Benefits of Corrosive gas test chamber
- Integrated Environmental & Gas Control
Simultaneous and precise control of temperature, humidity and corrosive gas concentration
Supports single gas and mixed gas corrosion tests
Fully compliant with IEC 60068-2-42 and IEC 60068-2-60
- Multi-Gas Corrosion Simulation
Supported gases include SO₂, H₂S, NO₂, NH₃, Cl₂
ppb-level concentration control for reliable accelerated corrosion testing
Suitable for mild, moderate and severe corrosion simulation programs
- High Sealing & Safe Gas Management
Optimized chamber sealing structure minimizes gas leakage risk
Integrated exhaust gas treatment unit ensures safe and efficient discharge
Continuous gas concentration monitoring throughout the test process
- One-Stop Customized Solution
From test requirement analysis to design, production, installation and commissioning
Customizable chamber size, gas configuration and test profiles
Professional technical support throughout the entire project lifecycle
Specifications of Noxious Gas Test Chamber
Model GCM-100 GCM-225 GCM-500
Internal Dimensions (mm) 400*500*500 500*600*750 700*800*900
Overall Dimensions (mm) 1010*1050*1620 1110*1150*1860 1330*1350*2010
Interior Volume (L) 100 225 500
Temperature Range 15 ℃ ~ 80 ℃
Temperature Fluctuation ± 0.5 ℃
Temperature Deviation ± 2.0 ℃
Humidity Range 30% ~ 98% RH
Humidity Deviation ±2.5% RH
SO2 Concentration 100 ~500 ppb± 20 ppb (Adjustable)
H2S Concentration 10 ~100 ppb ± 20 ppb (Adjustable)
NO2 Concentration 200 ppb ± 20 ppb (Adjustable)
Cl2 Concentration 10 ~20 ppb ±5 ppb (Adjustable)
Air Change Rate 3~10times /h
Cooling system Mechanical compression refrigeration system
Humidifier External isolation, stainless steel surface evaporation humidifier
Water Supply System Water purification system, Automatic water supply
Controller Programmable color LCD touch screen controller. Ethernet connection, PC Link
Gas Sensor H2S/NO2/CL2/SO² gas sensor
Air Circulation Centrifugal wind fan
Door Lock Electromagnetic lock
Gas Exhaust Device Exhaust Unit
Safety Device Humidifier Dry-combustion Protection; Over-temperature Protection; Over-current Protection;Water Shortage Protection; Earth leakage Protection
Interior material SUS316 stainless steel +Glass fiber reinforced plastics
Exterior material Steel Plate with protective coating
Noxious Gas Test Chamber Working Principle
Test samples are placed inside the sealed test chamber
Corrosive gas (single or mixed) is precisely injected via high-accuracy flow control
Uniform gas distribution is achieved through centrifugal air circulation
Temperature, humidity and gas concentration are continuously monitored
After testing, exhaust gas is purified and safely discharged
Operators can observe sample changes in real time through the inspection window.
Product Design Details of Noxious Gas Test Chamber
High-Sealing Chamber Structure
Independent Gas Delivery
Multi-layer sealing design with corrosion-resistant materials effectively prevents toxic gas leakage, while an electromagnetic safety door lock prevents accidental opening during operation, ensuring operator safety and stable gas concentration throughout long-duration testing.
Each gas is supplied through an independent pipeline controlled by high-precision mass flow controllers, eliminating cross-contamination and guaranteeing accurate mixed gas ratios.
Real-Time Gas Concentration Monitoring
Corrosion-Resistant Workroom
Integrated H₂S, SO₂, NO₂ and Cl₂ sensors continuously monitor gas concentration and provide closed-loop feedback control to maintain stable test conditions.
The noxious gas chamber interior is constructed from SUS316 stainless steel, providing excellent resistance to aggressive corrosive environments and long service life.
Exhaust Gas Treatment
Smart Control & Easy Maintenance
The exhaust gas is neutralized using an NaOH solution, with a built-in spray system inside the solution tank to enhance gas–liquid contact and accelerate exhaust gas treatment, ensuring safe and efficient discharge after testing.
Programmable color LCD touch screen controller with Ethernet and PC connection allows intuitive operation, remote monitoring and simplified maintenance.
Contact LIB industry today to receive a technical proposal tailored to your IEC testing requirements.
Our solution includes professional pre-sales consultation, on-site installation and commissioning, operator training, a 3-year warranty, lifelong technical support, and responsive English-speaking service, ensuring long-term reliability and worry-free operation throughout the entire equipment lifecycle.
As a trustworthy and reliable environmental chamber manufacturers, we provide you with environmental chamber.